Topic 8.5
Electric flux
How much field passes through a surface: the area vector, orientation and the surface integral.
6 min read2 worked examples3 questions to check yourself
Big idea
Electric flux measures how much electric field passes through a surface: the component of the field perpendicular to the surface, multiplied by the area and added up over the whole surface.
A flat surface seen edge-on in a uniform field. The area vector is perpendicular to the surface, and is the angle between and the field. The flux is : tilting the surface lets fewer field lines through it.
Explanation
For a flat surface of area in a uniform field, the flux depends on three things: the field's strength, the area, and how the surface is tilted. The tilt is described by the area vector , whose magnitude is the area and whose direction is perpendicular to the surface. Then , where is the angle between the field and the perpendicular, not between the field and the surface itself. Face-on to the field () the flux is ; edge-on () the field skims past and the flux is zero. In the field-line picture, flux counts the lines that pass through.
Flux is a scalar, but it has a sign: positive when the field goes through in the direction of , negative when it goes through the other way. For an open surface you choose which perpendicular to call . For a closed surface, such as a box or a sphere, the convention is fixed: points outward, so field leaving the enclosed volume counts as positive flux and field entering counts as negative.
When the field changes from place to place, or the surface is curved, cut the surface into patches small enough to be flat with a uniform field across each. Each patch contributes , and the total is the surface integral . Choosing strips or rings along which and the angle are constant turns the surface integral into an ordinary one.
Equations
The flux of a uniform field through a flat surface is the field's component along the surface's perpendicular, multiplied by the area.
- electric flux through the surface (N·m²/C)
- electric field (uniform over the surface) (N/C)
- area vector: magnitude is the area, direction is perpendicular to the surface (m²)
- angle between the field and the area vector (° or rad)
- Use it when
A flat surface in a field that is the same at every point of it.
- Not when
Do not use the angle between the field and the surface: if that angle is given, is minus it. Not valid when the field varies across the surface.
In general, flux is the sum over all small patches of the surface of the perpendicular field component multiplied by the patch's area.
- electric flux through the surface (N·m²/C)
- electric field at the patch (N/C)
- area; $d\vec{A}$ is a small patch's area vector, outward for a closed surface (m²)
- Use it when
The field's size or direction changes over the surface, or the surface is curved.
- Not when
No need to integrate when the field is uniform and the surface flat; the product above is the same thing.
Where it comes from
Flux of a point charge through a disc. A point charge sits on the axis of a flat disc of radius , a distance from its centre. The field is neither uniform over the disc nor perpendicular to it, so cut the disc into rings of radius and width , each of area . Every point of one ring is a distance from the charge, so the field there has size and makes an angle with the disc's perpendicular, with . Then
Let , so :
using . For a very large disc () the flux tends to whatever the distance : half of the charge's field lines pass through an infinite plane to one side of it. All of them together carry , which is Gauss's law (topic 8.6).
Worked examples
Flux through a tilted sheet
Step by stepA flat rectangular sheet measuring by is placed in a uniform electric field of . The field makes an angle of with the plane of the sheet. What is the magnitude of the electric flux through the sheet?
- Step 1:
Find the area: .
- Step 2:
Find the right angle. The formula needs the angle between the field and the perpendicular to the sheet. The field is from the sheet's plane, so it is from the perpendicular.
- Step 3:
.
0 of 3 stepsAnswer
- Step 1:
Flux of a field that varies across the surface
Written as an exam answerIn a region of space the electric field points in the direction and its magnitude grows with the distance from the z-axis: , where . A flat disk of radius lies in the xy-plane, centred on the z-axis, with its area vector in the direction. Calculate the electric flux through the disk.
- Step 1:
The field is perpendicular to the disk everywhere, so , but its magnitude is not the same everywhere, so cannot be used directly.
- Step 2:
depends only on . Cut the disk into thin rings of radius and width , each of area . Around one ring the field is constant, so .
- Step 3:
Integrate out to the rim, : .
- Step 4:
.
- Step 5:
Check: the field reaches at the rim, but its average over the disk, weighted toward the rim, is : .
Answer
- Step 1:
Common mistakes
Mistake
The flux through a surface is zero, so the electric field at the surface is zero.
What is true
Flux can be zero with a strong field present: the field may run parallel to the surface, or as much may go in through a closed surface as comes out.
Mistake
Flux is just another word for how strong the field is.
What is true
Field is a vector at a point, in . Flux is a scalar that belongs to a whole surface, in . The same field gives different fluxes through surfaces of different area or tilt.
Mistake
In , is the angle between the field and the surface.
What is true
is measured from the perpendicular to the surface. A field lying in the surface has and gives zero flux, not the maximum.
Check yourself
- 1.
The dashed box is a closed surface in a uniform field. What is the net flux through it?
Zero. With outward area vectors, the left face has flux (field entering), the right face (field leaving), and the other faces are parallel to the field. Every line that goes in comes out.
- 2.
A flat loop of area sits in a uniform field of . What is the largest flux it can have, and at what angle between the field and the loop's perpendicular is the flux half of that?
The largest is , with the loop face-on. Half needs , so .
- 3.
For a closed surface, what does negative net flux tell you about the field lines?
More lines enter the surface than leave it. Lines end inside, which (topic 8.6) means there is net negative charge in there.
Try it
Turn the surface in a uniform field. The flux is : largest face-on, zero edge-on at , and negative once the area vector points against the field.
Builds on
Practice 8.5 with feedback
Problem sets for Unit 8 grade themselves, and Raise hints at the next step instead of giving the answer.
Spotted a mistake in this lesson? Tell us and we will fix it.